Selector Switch Complete Assemblies
Dual Element Fuses


Displaying: 25 - 47 of 47 Matching Items
47 Items
View:
Active Filters :
Part #:BUSS LPJ-1SP

CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 1 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 92.58
Part #:BUSS LPJ-30SP

CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 97.20
Part #:BUSS LPJ-25SP

CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 25 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 90.56
Part #:BUSS LPJ-60SP

CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 60 AMP CURRENT RATING FERRULE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT CONTACT MATERIAL SILVER PLATED APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL LPJ MODEL
$ 149.24
Part #:BUSS LPS-RK-50SP

CLASS RK1 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMP SYMMETRICAL, 100 KILOAMP (DC) INTERRUPTING RATING 50 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND CONTACT MATERIAL SILVER PLATED APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH LPS-RK MODEL
$ 106.36
Part #:GE CR104PSG21B91

KNOB TYPE 30.5 MM SIZE 1NO-1NC CONTACT CONFIGURATION MAINTAINED OPERATION TYPE 600 VAC/VDC 10 AMPERE CONTACT RATING UL, CUL, CSA APPROVAL NEMA 1/3/3R/3S/4/4X/12/13 ENCLOSURE NYLON BODY MATERIAL 2 POSITION(S) CHROMIUM PLATED ZINC INGOT BEZEL MATERIAL POLYCARBONATE ACTUATOR MATERIAL LEFT-RIGHT THROW 1 CAM CODE BLACK KNOB COLOR APPLICABLE STANDARD IEC 947-5-1 OPERATING TEMPERATURE -13 TO 158 DEG F WIRE SIZE 22 TO 12 AWG COPPER CR104P MODEL
$ 40.20
Part #:BUSS FRN-R-10

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 31.46
Part #:BUSS FRN-R-20

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VOLT AC, 125 VOLT DC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING BLADE TERMINAL TYPE 8 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRN-R MODEL
$ 24.08
Part #:BUSS FRN-R-30

CLASS RK5 TYPE 2 INCH UL 248-12, CSA C22.2, CE APPROVAL 250 VAC/125 VDC VOLTAGE RATING 0.56 INCH DIAMETER 200 KILOAMPERE (SYMMETRICAL), 20 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT SERIES FRN-R MODEL
$ 24.08
Part #:BUSS FRS-R-10

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 10 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 53.46
Part #:BUSS FRS-R-100

CLASS RK5 TYPE 7.88 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 1.11 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 100 AMP CURRENT RATING BLADE TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 149.20
Part #:BUSS FRS-R-15

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 15 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Part #:BUSS FRS-R-20

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 20 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Part #:BUSS FRS-R-25

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 25 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Part #:BUSS FRS-R-30

CLASS RK5 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 300 VOLT DC VOLTAGE RATING 0.81 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 30 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 47.38
Part #:BUSS FRS-R-40

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 40 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS FRS-R-60

CLASS RK5 TYPE 5.5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VOLT AC, 250 VOLT DC VOLTAGE RATING 1.06 INCH DIAMETER 200 KILOAMP SYMMETRICAL (AC), 20 KILOAMP (DC) INTERRUPTING RATING 60 AMP CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 10 SECOND TIME DELAY AT 500 PERCENT RATED LOAD, DUAL ELEMENT, NON-INDICATING CHARACTERISTICS FUSETRON[TM] BRAND APPLICATION POWER PANELBOARD, MOTOR CONTROL CENTER, COMBINATION STARTER, MACHINERY DISCONNECT FRS-R MODEL
$ 81.60
Part #:BUSS LPJ-20SP

CLASS J TYPE 2.25 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 20 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 89.34
Part #:BUSS LPJ-35SP

CLASS J TYPE 2.38 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 35 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 151.84
Part #:BUSS LPJ-40SP

CLASS J TYPE 2.38 INCH UL, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.06 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 40 AMPERE CURRENT RATING FERRULE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND ROHS COMPLIANT APPLICATION POWER PANELBOARD, BRANCH CIRCUIT BREAKER PANELBOARD MAIN, MACHINERY DISCONNECT, INDUSTRIAL CONTROL SERIES LPJ MODEL
$ 147.78
Part #:BUSS LPS-RK-200SP

CLASS RK1 TYPE 9.63 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 1.66 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 200 AMPERE CURRENT RATING BLADE TERMINAL TYPE 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$ 535.94
Part #:BUSS LPS-RK-25SP

CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 25 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$ 75.26
Part #:BUSS LPS-RK-30SP

CLASS RK1 TYPE 5 INCH UL 248-12, CSA C22.2, CE APPROVAL 600 VAC/300 VDC VOLTAGE RATING 0.81 INCH DIAMETER 300 KILOAMPERE (SYMMETRICAL), 100 KILOAMPERE (DC) INTERRUPTING RATING 30 AMPERE CURRENT RATING FERRULE WITH GROOVED RING TERMINAL TYPE 8 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT, NON-INDICATING CHARACTERISTICS LOW-PEAK[TM] BRAND APPLICATION LARGE DISTRIBUTION SWITCHBOARD, POWER PANELBOARD, MOTOR CONTROL CENTER, MACHINERY DISCONNECT SWITCH SERIES LPS-RK MODEL
$ 75.26
 
Displaying: 25 - 47 of 47 Matching Items